Electrical
Min. weight that fires one cell. 6 cells per tile = 6 × W kg trigger load.
Body weight acts on the stepped tile (often 1 foot, ≈½ body weight).
1.0 = static (standing). ~0.6–0.8 typical mid-stride.
Normal adult ≈ 14 steps / 10 m (stride ≈ 0.7 m).
Empty mall corridor: ~50. Busy station walkway: ~1000–2000.
Physical / material
Spec sheet: 150 g (50 mm × 25 mm piezo disc).
6061-T6: 2.70. 7075: 2.81. Cast Al: 2.6–2.8.
Plastic-ceramic composite: 1.5–2.2 typical. Glass-filled PA: 1.5. Mineral-filled PP: 1.8–2.1.
—
Hexes in 1 m × 1 m
—
Area per hex (cm²)
—
Active cells / step
—
Power per tile per step (mW)
—
Power per 10 m pass (W)
—
Energy per person-hour (Wh)
—
Per m² per 12 h (busy walkway)
—
Per m² per 24 h (your traffic)
—
Per m² per year (kWh)
—
Load per cell (kg)
Mass & BOM
—
Generators / tile (6 × per hex)
—
Aluminium tile (kg)
—
Composite support (kg)
—
TOTAL per tile (kg)
—
kg / m² (loaded pavement)
—
Pavement total (kg)
—
Pavement total (tonnes)
—
Generators in pavement
—
Equivalent static load (kN/m²)
Mass formulas (per hex tile)
- Hex area:
A = (3√3 / 2) · L²(L in metres). - Generators:
6 × m_gen(six corner cells). - Aluminium:
ρ_Al · A · t_tile / 1000kg (ρ in g/cm³, t in mm). - Support:
ρ_PC · A · t_supp / 1000kg. - Total per tile: sum of the three above.
- kg / m² = total_per_tile × hexes_per_m².
- Pavement total = kg / m² × area.
- Static load (kN/m²) = (kg / m²) × 9.81 / 1000.
Pavement 2 m × 10 m
—
Total hexes in pavement
—
Total load cells
—
kWh / year (whole pavement)
—
kg CO₂ avoided / year
—
LED-on hours / year (your LED)
—
Phone-charges / year (10 Wh each)
How the pavement totals are calculated
- Pavement area = W × L (default 2 m × 10 m = 20 m²).
- Total hexes = hexes_per_m² × area (same hex size as the 1 m × 1 m view).
- Total cells = total hexes × 6 corners.
- Pavement kWh/yr = per-m² kWh/yr × area.
- CO₂ avoided = kWh × 0.6 kg CO₂/kWh (HK grid emission factor, CLP 2023 published).
- LED-on hours = kWh × 1000 / LED_W (assumes continuous drain at the stated wattage).
- Phone-charges = kWh × 1000 / 10 Wh (typical partial phone top-up).
Formulas used (electrical)
- Hex area:
A = (3√3 / 2) · L² - Hex width (pointy-top):
w = √3 · L, height:h = 2 · L - Hexes per 1 m²:
cols = ⌊1 / w⌋,rows = ⌊1 / h⌋, totalcols · rows - Trigger load per cell:
W. Cells per tile: 6 (one per corner joint). - Force on stepped tile:
F = body · foot_sharekg. - Active cells:
n = clamp(round(F / W), 1, 6). - Power per tile per step:
P = n · mW_cell. - Power per 10 m pass:
P · steps / 1000W (assuming each step on a fresh tile). - Sustained W/m² at 1 step/s:
P · (hexes_per_m²) / 1000. - Daily kWh / m² at 0.5 step/s for 12 h:
P · 0.5 · 43200 / 3.6e6.